Use of electronically controlled explosion-proof fire water cannon
1. According to the actual situation of the fire and the nature of the fire, choose the DC or spray function of the water cannon.
2. The up button is to operate the gun head to move upwards, the down button is to operate the gun head to move downwards, the left button is to move the gun body to the left, the right button is to operate the gun body to the right, and the start button is to open the water cannon. Water electric valve, the stop button is to close the water gun into the water electric valve.
The remote control is a control four, and there are four selection keys corresponding to four fire cannons respectively. When a fire occurs on the scene, the corresponding fire cannon is turned on to extinguish the fire, the gun head is adjusted to the fire source and the water cannon inlet valve is opened. Observe the water drop point to ensure that the fire point is covered. If it is not, adjust it to the appropriate position. After the fire is over, close the water inlet electric valve.
3. After the fire cannon is used, rinse with clean water, fill the oil hole with oil, and check whether the rotating parts are flexible and normal, adjust the gun head down, and then drain the turret water pipe.
Operation, maintenance and maintenance of electronically controlled explosion-proof fire water cannon
1. The electric fire gun should check the controller power circuit and the wireless remote control receiving device before use to ensure that the current and voltage are within the normal range. The battery power in the remote controller is normal.
2. Keep the firearm body clean, use foam to extinguish the fire and rinse it with clean water.
3. Regularly add grease to the grease mouth and the rotating part to ensure flexible rotation.
4. If the injection pressure is too high or the range is close, check whether there is gambling on the nozzle, and if it should be removed in time.
5. Before installing the fire monitor, the pipeline must be flushed to prevent debris from entering the fire gun and blocking the nozzle.
6. All parts should be kept intact. If the fasteners are found to be loose, they should be repaired in time.
7. If the fire monitor is used for a long time, the surface should be treated accordingly.
8. When entering the winter, the residual water in the fire cannon should be released to avoid freezing the gun body.
9. Fire-fighting guns should be used in downwind conditions when using them.
Chain Link Temporary Fence
Chain Link Temporary Fence panel is also known as American temporary fence, temporary chain link fence, portable fence, no dig fence,temp fencing and mobile fence.It is consist of chain link panel, round tube frame, steel feet, optional stays and clamps.This kind of fence has a superior structure, mobility and environmental suitability is very good.
Chain Link Temporary Fence Specification
|
|
4ft, 6ft, 8ft
|
Fence width/length
|
10ft, 12ft, 14ft, etc
|
Wire diameter
|
2.7mm, 2.5mm, 3mm
|
Chain link mesh size
|
57x57mm (2-1/4"), 50x50mm, 60x60mm, etc.
|
Frame tube O.D
|
33.4mm (1-3/8"), 32mm, or 42mm (1-5/8") with 0.065" wall thickness
|
Vertical/cross brace tube O.D
|
25mm or 32mm with 1.6mm (0.065") wall thickness
|
Fence base/stand
|
610x590mm, 762x460mm, etc
|
Accessories
|
clamps, base feet, tension wire and tension bar (optional)
|
Material
|
hot dipped galvanized
|
Surface treatment
|
All joints are welded and sprayed with a galvanized paint to cover any exposed metal
|
Chain Link Fence,Temporary Chain Link Fence,Chain Link Fabric Mesh,Chain Link Mesh Fence
Hebei Yicheng Wire Mesh Products Co., Ltd , https://www.yc-fence.com